Expert calibration lab in
Roissy – France
Opening hours
294/296, avenue du bois de la pie
95700 ROISSY-EN-France

CAPABILITIES
Radiometry / Photometry
Global Calibration Scope
- Illuminance: 0.5 to 20 000 lux
- Luminance: 0.2 to 15 000 ㏅/m2…
Common equipment serviced: Illuminance meter, Luminance meter, Spectrophotometer, Glossmeter, Photometer, Colorimeter, Pyranometer, Irradiance meter
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Dimensional
Global Calibration Scope
- Gauge block (steel, tungsten carbide, ceramic…): up to 1500 mm
- Long length (standard tape rules, peripheral gauges…): up to 100 m
Common equipment serviced: Angle instruments, Measuring bench/optical, Depth gauge, Gauge blocks, Height gauges, Micrometers, Length instruments, Limit gauges, Form and surface, Thread gauges
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Chemical
Global Calibration Scope
- Viscosity: kinematic and dynamic, consistometric cup, etc.
- Conductivity: Electrical (0 μS/cm to 200 mS/cm) and with Certified Reference Material (1,1 μS/cm to 111,3 mS/cm)
- Gas detector and Gas Concentration : Carbon monoxide, Nitrogen monoxide, Nitrogen dioxide, Oxygen, Total gaseous organic carbon, Dilution apparatus for olfactometry, Sulfur dioxide, Carbon dioxide, Hydrogen sulfide, Benzene, Methane, Ozone, Propane, etc.
- Refractometry: (1.33 ~ 1.62) nD (refractive index), 0 to 87.6% Brix, etc.
Common equipment serviced: Conductivity meters, Salinity meters, pH meters, Sucrose solutions, Gas detectors and gas concentration, Particle counters, Refractometry instruments, Viscosity instruments
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Electricity
Laboratoire : Calibrateurs, Multimètres, Pinces Multifonction, Boîtes de résistance, Hyperfréquences, Hautes tensions…
Site : Mesure des grandeurs U, I, R
Force
Laboratoire : Clés et tournevis dynamométriques, dynamomètres…
Humidity
Global Calibration Scope
- Dew Point sensors ranging -90° C to +95° C
- RH from 0% – 100%
Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Laboratoire et site : Manomètres, capteurs de pression…
Pression de -1 bar à 700 bar
Temperature
Site : Enceintes climatiques, Bains, Thermocycleurs, Fours, Étuves…
Température de -80 °C à 1 250 °C
Time / Frequency
Laboratoire : Oscilloscopes, Tachymètres, Centrifugeuses, Fréquencemètres, Générateurs de fonction…
Torque
Laboratoire : Clés et tournevis dynamométriques, dynamomètres…
Thermal and climatic testing
Caractérisations d’enceintes selon référentiels FD X15-140, IEC 60068, AMS 2750, NF L06-450, FDV 08-601
Laboratoire : Calibrateurs, Multimètres, Pinces Multifonction, Boîtes de résistance, Hyperfréquences, Hautes tensions…
Site : Mesure des grandeurs U, I, R
Laboratoire : Clés et tournevis dynamométriques, dynamomètres…
Laboratoire et site : Manomètres, capteurs de pression…
Pression de -1 bar à 700 bar
Site : Enceintes climatiques, Bains, Thermocycleurs, Fours, Étuves…
Température de -80 °C à 1 250 °C
Laboratoire : Oscilloscopes, Tachymètres, Centrifugeuses, Fréquencemètres, Générateurs de fonction…
Laboratoire : Clés et tournevis dynamométriques, dynamomètres…
Caractérisations d’enceintes selon référentiels FD X15-140, IEC 60068, AMS 2750, NF L06-450, FDV 08-601